Call us: 08045812898
We are a remarkable entity, engaged in offering high quality Automatic Biochemistry Analyzer that is used in the hospital and other related places for biochemical tests. This analyzer is manufactured using advanced engineering concepts and basic components as per the defined industrial norms. Also, this equipment is precisely examined by our deft quality inspectors to ensure its trouble free working. Clients can avail this Semi Automatic Biochemistry Analyzer from us in several technical specification at industry leading rate.
METHODS OF CALCULATION
METHODS OF ASSAY
ABS/EP with Factor/KIN/Fix Time/Differential/ Multi point of 10 Standards.
Maximum Relative Humidity | 80 % |
Power Consumption | 80 W |
Weight | 6 Kg |
Temperature | 10 to 40 Degree C |
Model Name/Number | RX-50 |
Voltage | 110-220 V |
Frequency | 50 - 60 Hz |
Dimensions | 36 cm x 41 cm x 15 cm |
Brand | Micro Lab |
Usage/Application | Laboratory |
Instrument Name | Biochemistry Analyzer |
OPTICAL SYSTEM
| Principle | Absorption spectrometry |
| Range of measurement | From 0.1 to 3.0A for 340nm, 0.1 to 3.5A WL range 405 to 670nm |
| Nominal spectral range | Automatic via filter wheel |
| Filters | 340, 405, 450, 505, 546, 578, 630 and 670nm interference type |
| Bandwidth | 8 nm (+ 2nm) |
| Reading error | + 5% at 0.10 A |
| Light source | Quartz Halogen lamp 12 V / 20 W, 2000 hours |
| Zero | Automatic |
| Settings | Monochromatic and Bichromatic readings. |
| Detector | Schottkey type Photodiode - Silicon |
THERMOSTAT SYSTEM
| Peltier regulated 25o, 30o & 37oC, RT programmed | |
| Accuracy | + 0.1oC |
CUVETTES - DUAL MODE
| Flow cell of 18µL | |
| Removable cuvettes | Square micro plastic cuvettes & Round test tube diameter 13mm |
PRINTER
| Type | Fast Thermal Graphic |
| Printing speed | 50 mm/sec |
| Dots per line | 384 dots/line |
| Paper | Thermo sensitive, 57 mm wide |
| RS232 | For PC Connection |
SCREEN AND KEYBOARD
| LCD blue LED back lit | 240 x 128 pixels |
| Keyboard | Tactile Soft - Touch |
ASPIRATION SYSTEM
| Continuous flow cell system with peristaltic pump. |
| Sipping Reagent volume programmable from 100µL to 2000µL Air purge volume: programmable from 30µL to 150µL |
PROGRAMMING
| 235 Tests, 9 units, Quality control storage of the last 30 results. | |
| Memory | 128 KB EEPROM |
QUALITY CONTROL
| 2 Controls per test - Normal & Abnormal |
| Levy-Jennings charts |
POWER / DIMENSIONS
| Voltage | 110 - 220V + 10% |
| Frequency | 50 - 60 Hz |
| Maximum power | <80W |
| Temperature | 10oC to 40oC |
| Maximum relative humidity | 80% |
| Dimensions | 38 cm x 41 cmx 15 cm |
| Weight | 6 kgs |